5 Repair
5.3.1 Replacing the upper cable package
Continued
Securing the upper cable package to the housing
1
2
3
Reconnecting the axis-4 motor connectors
1
Continues on next page
156
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Refit the cable bracket.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
© Copyright 2019-2022 ABB. All rights reserved.
Note
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 0.8 Nm
xx1800003013
Screw: M2.5x6 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 0.6 Nm
xx1800003014