6 Calibration
6.3.1 Updating revolution counters on OmniCore robots
Continued
2
3
Continues on next page
718
Action
Inspect the cable harness status.
The cable harness must be in vertical state as
shown in the figure.
If the cable harness twists towards left,
proceed to step 3.
If the cable harness twists towards right,
proceed to step 4.
Cable harness twisting towards left
Jog the axis 4 anti-clockwise (with the operator
facing the rear) until the cable harness is in vertic-
al state.