5 Repair
5.7.1 Replacing the axis-1 motor
Continued
7
Refitting the motor
Use these procedures to refit the axis-1 motor.
Refitting the axis-1 motor
1
2
3
Continues on next page
500
Action
Remove the timing belt from its groove on the
motor.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check that:
all assembly surfaces are clean and without
damages
the motor is clean and undamaged.
Check the cooling pad.
Replace if damaged.
© Copyright 2019-2022 ABB. All rights reserved.
Note
xx1800003614
Note
Cooling pad for axis-1 and -2 mo-
tors: 3HAC071020-001
xx1800003602
Product manual - IRB 1100