Action
Reconnect the air hoses in a cross pattern.
Tip
See the number markings on the air hoses for
help to find the corresponding air hoses.
The air hoses with the same number connect to
the same Y-shaped connector.
For robots with CP/CS cabling
Reconnect the connector.
J5.C1
For robots with Ethernet cabling
Reconnect the connector J5.C2 using the tool.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.1 Replacing the housing
Continued
Note
xx1800002945
xx1800002947
J5.C2 connector assembly tool, in-
cluded in the special toolkit
3HAC071022-001
xx1800002948
Continues on next page