ABB IRB 1100 Product Manual page 352

Hide thumbs Also See for IRB 1100:
Table of Contents

Advertisement

5 Repair
5.5.1 Replacing the lower arm
Continued
3
Disconnecting the air hoses, CP/CS cabling and Ethernet cabling (if equipped)
1
2
3
Continues on next page
352
Action
Remove the cable bracket.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
CAUTION
For robots with protection type Clean Room
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
replacing parts on page
123.
Disconnect the air hoses from the Y-shaped con-
nectors.
© Copyright 2019-2022 ABB. All rights reserved.
Note
xx1800002499