This machine have the following test print TYPE and you can judge the image failure that is checked as "Yes" in the following image check items with each test print.
If the image failure occurred on normal output does not reappear on the test print, it may be caused by the PDL input or reader side.
Select the test print TYPE
NO.
TYPE Pattern
SELECT NO.01
Grid
SELECT NO.02
Half-tone
SELECT NO.03
All-black
SELECT NO.04
---(For R&D)
SELECT NO.05
---(For R&D)
SELECT NO.06
4dot-6space (vertical)
SELECT NO.07
4dot-6space (horizontal)
SELECT NO.08
---(For R&D)
SELECT NO.09
16 gray levels
(monochromatic)
Procedure
1) Enter the PG number with numeric keys, then press the START key.
2) Select single-sided (SGL: 0) or double-sided (DBL: 1), then press the START key.
3) Enter the number of prints to be output (PG COUNT), then press the START key.
4) Specify the paper drawer (main unit), then press the START key.
Main unit cassette (ST_C: 0), 2nd cassette (OP_C: 1), Manual feed tray (MLT: 2)
5) Specify the paper eject slot, then press the START key.
Tray 1 (1_OUT: 0), Tray2 (2_OUT: 1)
6) Select a paper type, then press the OK key.