Motorola PowerQUICC II MPC8280 Series Reference Manual page 1243

Table of Contents

Advertisement

Offset
Name
0x19
LINK 10 INFO
0x1A
LINK 9 INFO
0x1B
LINK 8 INFO
0x1C
LINK 15 INFO
0x1D
LINK 14 INFO
0x1E
LINK 13 INFO
0x1F
LINK 12 INFO
0x20
LINK 19 INFO
0x21
LINK 18 INFO
0x22
LINK 17 INFO
0x23
LINK 16 INFO
0x24
LINK 23 INFO
0x25
LINK 22 INFO
0x26
LINK 21 INFO
0x27
LINK 20 INFO
0x28
LINK 27 INFO
0x29
LINK 26 INFO
0x2A
LINK 25 INFO
0x2B
LINK 24 INFO
0x2C
LINK 31 INFO
0x2D
LINK 30 INFO
0x2E
LINK 29 INFO
0x2F
LINK 28 INFO
0x30
CRC10
0x32
END-TO-END
CHANNEL
0x33
UNUSED
0x34
TAG
1
Boldfaced entries in the above table indicate parameters which must be initialized by the user. All other
parameters are managed by the microcode and should be initialized to zero unless otherwise stated.
MOTOROLA
Freescale Semiconductor, Inc.
Table 34-9. ICP Cell Template (continued)
Width
Byte
Status and control of link with LID = 10
Byte
Status and control of link with LID = 9
Byte
Status and control of link with LID = 8
Byte
Status and control of link with LID = 15
Byte
Status and control of link with LID = 14
Byte
Status and control of link with LID = 13
Byte
Status and control of link with LID = 12
Byte
Status and control of link with LID = 19
Byte
Status and control of link with LID = 18
Byte
Status and control of link with LID = 17
Byte
Status and control of link with LID = 16
Byte
Status and control of link with LID = 23
Byte
Status and control of link with LID = 22
Byte
Status and control of link with LID = 21
Byte
Status and control of link with LID = 20
Byte
Status and control of link with LID = 27
Byte
Status and control of link with LID = 26
Byte
Status and control of link with LID = 25
Byte
Status and control of link with LID = 24
Byte
Program to 0x00.
Byte
Status and control of link with LID = 30
Byte
Status and control of link with LID = 29
Byte
Status and control of link with LID = 28
Hword
Microcode-managed area. Microcode will program this field
dynamically.
Byte
Program to any value desired for end-to-end
implementation-dependent signalling, or program to 0x00 if unused.
Byte
Program to 0x6A.
Byte
Internally-used tag value indicating that this is an ICP cell. Program to
0x80.
Chapter 34. Inverse Multiplexing for ATM (IMA)
For More Information On This Product,
Go to: www.freescale.com
IMA Programming Model
1
Description
34-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerquicc ii mpc8270Powerquicc ii mpc8275Powerquicc ii mpc8280

Table of Contents