[Channel %1: ] Block %2 illegal retract plane with WAB
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
By means of DISRP a position of the retraction plane has been programmed which is not situated between the safety
distance (DISCL) and the starting point (during approach) and/or end point (during retraction) of the WAB movement.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10771
[Channel %1: ] Block %2 overflow of local block buffer due to orientation smoothing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
This error occurs when more blocks must be buffered than memory space is available.
This error can only occur when the software has been incorrectly configured.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Increase size of local buffer area.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10790
[Channel %1: ] Block %2 plane change during linear programming with angles
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The active plane was changed between the first and second subblock when programming two straight lines with angle
parameters.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10791
[Channel %1: ] Block %2 invalid angle during linear programming
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No intermediate point was found when programming a contour consisting of two straight lines and an angle specifica-
tion.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents