Block %2 Parts Program Command %3 Not Executable; Block %2 Wrong Value Or Wrong Number Of Parameters On Function - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14018
[Channel %1: ] Block %2 parts program command %3 not executable (protection level
setpoint value / actual value: %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Programmed command
%4 = Protection level of the command / current protection level
Definitions:
To parts program command %3, a protection level has been assigned that is logically higher (smaller in value) than
the current access right, or the command does not exist in the current control configuration.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify parts program. Please see the Siemens Progamming Guide or OEM documentation for the language com-
mands permissible for the relevant system configuration.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14020
[Channel %1: ] Block %2 wrong value or wrong number of parameters on function or
procedure call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- An illegal parameter value was specified in a function or procedure call.
- An illegal number of actual parameters was programmed in a function or procedure call.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14021
[Channel %1: ] Block %2 wrong value or wrong number of parameters on function or
procedure call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- An illegal parameter value was specified in a function or procedure call.
- An illegal number of actual parameters was programmed in a function or procedure call.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
145