NCK alarms
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12560
[Channel %1: ] Block %2 programmed value %3 exceeds allowed limits
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
In a value assignment, the permissible value range of the data type has been exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block.
Assign value within the value range of the various data types, or if necessary use another type in order to increase the
size of the value range, e.g. INT ->REAL.
Value ranges of the various variable types:
- REAL: Property: Fractional number with dec. pt., value range: +/-(2-1022-2+1023)
- INT: Property: Integers with signs, value range: +/-(231-1)
- BOOL: Property: Truth value TRUE, FALSE, value range: 0,1
- CHAR: Property: 1 ASCII character, value range: 0-255
- STRING: Property: Character string (max. 100 values), value range: 0-255
- AXIS: Property: Axis addresses, value range: Axis names only
- FRAME: Property: Geometric information, value range: As for axis paths
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12573
[Channel %1: ] Block %2 motion-synchronous action: Call by reference parameters not
allowed %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source text area
Definitions:
Call by reference parameters (keyword VAR) are not possible with technology cycles.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct PROC instruction of technology cycle.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
132