NCK alarms
4160
[Channel %1: ] Invalid M function number configured for spindle switchover
Parameters:
%1 = Channel number
Definitions:
An M function was specified in MD20094 $MC_SPIND_RIGID_TAPPING_M_NR in order to configure the M function
number for spindle switchover. The M function number is assigned by the system and cannot be used for the switcho-
ver (M1 to M5, M17, M30, M40 to M45).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function which is not used by the system (M1 to M5, M17, M30, M40 to M45) in MD20094
$MC_SPIND_RIGID_TAPPING_M_NR.
Program
Switch control OFF - ON.
Continuation:
4180

Invalid M function number assigned to enable ASUP

Definitions:
An invalid M function number has been assigned for activation of ASUP. An illegal M number has been assigned in
MD10804 $MN_EXTERN_M_NO_SET_INT or MD10806 $MN_EXTERN_M_NO_DISABLE_INT for the configuration
of the M number range for activation/deactivation of the interrupt program.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check MD10804 $MN_EXTERN_M_NO_SET_INT and MD10806 $MN_EXTERN_M_NO_DISABLE_INT.
Program
Switch control OFF - ON.
Continuation:
4181
[Channel %1: ] Invalid assignment of an M auxiliary function number
Parameters:
%1 = Channel number
Definitions:
In MD22254 $MC_AUXFU_ASSOC_M0_VALUE or MD22256 $MC_AUXFU_ASSOC_M1_VALUE, a number has
been specified for the configuration of a new predefined M function which is occupied by the system, and cannot be
used for an assignment. (M0 to M5, M17, M30, M40 to M45).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function in machine data MD22254 $MC_AUXFU_ASSOC_M0_VALUE or MD22256
$MC_AUXFU_ASSOC_M1_VALUE which is not occupied by the system (M1 to M5, M17, M30, M40 to M45).
Program
Switch control OFF - ON.
Continuation:
32
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0