Machine pushbutton panel for sinumerik 840d sl; sinumerik 840de sl; sinumerik one (80 pages)
Summary of Contents for Siemens Sinumerik 840D sl
Page 1
Based Safety Functions Sensor/Actuator Connection Description of Data Commissioning Diagnostics Valid for Control Interaction with SINUMERIK 840D sl other Functions SINUMERIK 840D sl (export version) Drive Appendix SINAMICS S120 Software version Index CNC Software 4.7 SP2 SINUMERIK Operate 4.7 Edition 10/15...
10/15 6FC5 397--4BP40--5BA3 Trademarks All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. We have checked that the contents of this document correspond to the hardware and software described.
Page 6
(observe indicators such as arrow or similar). This way you avoid me- chanical damage to the memory card or the device. S Only use memory cards that have been approved by Siemens for use with SI- NUMERIK. Even though the SINUMERIK keeps to the general industry stan-...
Page 8
The Safety Integrated functions of the SINUMERIK are generally certified by inde- pendent institutes. An up--to--date list of certified components is available on re- quest from your local Siemens office. If you have any questions relating to certi- fications that have not been completed, please ask your Siemens contact.
Page 42
SINAMICS booksize and chassis units (max. 2 units). S For the Safety Integrated function, only the explicitly released encoder systems may be used. A list of the Siemens encoders and motors permissible for Safety Integrated functions can be obtained from your local Siemens contact partner.
2. Recommission the drive unit and drives 3. Recommission Safety Integrated Or contact your regional Siemens office and ask for the password to be deleted (complete drive project must be made available). Parameter overview (see Chapter 8.2.2 ”Description of the parameters”)
Also see Chapter 8.2.2 ”Description of parameters”. 4.10 PLC drives SINUMERIK 840D sl allows both NC controlled as well as PLC controlled axes to be operated. The PLC controlled axes are addressed exclusively via the PLC user program. For implementing the safety functions, for the PLC axes, the Safety Integrated Basic and Extended Functions of the SINAMICS drive family are available.
Configuring and parameterizing the PROFIsafe I/O The configuration of the PROFIBUS/PROFINET I/O connections on the PLC side of a SINUMERIK 840D sl is defined using the Step7 component HW Config. There are two options: S Integrating Siemens fail--safe devices via the hardware catalog S Integrating third--party fail--safe devices by importing the corresponding generic station description files.
F--CPUs. Data transfer is realized using the F_SENDDP blocks to send and F_RECVDP blocks to receive. The options as to how a SINUMERIK 840D sl with F_DP communication can be integrated is shown in Fig. 7-21. The F_DP communication is possible via PROFIBUS--DP (interface X126 or X136...
The start addresses (logical basis addresses) of the input and output areas of the F_DP communication at the I/O bus lines of a SINUMERIK 840D sl on the PLC side are defined when configuring the hardware using SIMATIC Step7 HW Config.
MD13334/13344 $MN_SAFE_SDP/RDP_LADDR. 7.4.2 Sender F_SENDDP In order to send SPL output data ($A_OUTSE) from one SINUMERIK 840D sl to another F--CPU using F_DP communication, an SPL connection must be para- meterized. An SPL connection comprises the following:...
FSDP[1...3].RETVAL15 or FSDP_HF[4..16].RETVAL15 7.4.3 Receiver F_RECVDP In order to transfer SPL output data from an F--CPU to a SINUMERIK 840D sl using F--DP communication, an SPL connection must be parameterized. This connection comprises the following: S F_DP communication relationship The following F_DP communication parameters are defined using the F_DP...
STARTER drive commissioning tool. However, the access stage is reduced as a result of a user--specific view for SINUMERIK 840D sl to 3 (expert access) so that the safety parameters for the motion monitoring functions are visible on the HMI without having to enter a password for the access stage.
Page 573
PRESS_LEVEL must be set to 0 during the acceptance test in order to avoid suppressing alarm outputs. S For SINUMERIK 840D sl, to document a test stop that has been carried out, it is sufficient to just log the test stop alarms of the NCK (27002); it is not abso- lutely necessary to log the test stop alarms of the SINAMICS S120 (C01798).