NCK alarms
61903
%[[Channel %1: ] Block %2: %]Label %4 not existing in the blank contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the labels exist in the blank contour
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61904
%[[Channel %1: ] Block %2: %]Label %4 not existing in the island contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the labels exist in the island contour
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61905
%[[Channel %1: ] Block %2: %]Label %4 not existing in the spigot contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the labels exist in the spigot contour
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61906
%[[Channel %1: ] Block %2: %]Label %4 not existing in the contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the labels exist in the contour
Program
Clear alarm with the RESET key. Restart part program
Continuation: