Definitions:
The desired tool motion command - triggered from the MMC or PLC - is not possible. The specified tool is not contained
in the specified magazine. (NCK cannot contain tools that are not assigned to a magazine. With this kind of tool, no
operations (motion, change) can be performed.)
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check that the specified tool is contained in the desired magazine, or program another tool to be changed.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22066
[Channel %1: ] Tool management: Tool change is not possible as tool %2 is not in
magazine %4.
Parameters:
%1 = Channel number
%2 = String (identifier)
%3 = -Not used-
%4 = Magazine no.
Definitions:
The desired tool change is not possible. The specified tool is not contained in the specified magazine. (NCK cannot
contain tools that are not assigned to a magazine. With this kind of tool, no operations (motion, change) can be per-
formed.)
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
- Check that the specified tool is contained in the desired magazine, or program another tool to be changed.
- Check whether the settings in machine data MD20110 $MC_RESET_MODE_MASK, MC20112
$MC_START_MODE_MASK and the associated machine data MD20122 $MC_TOOL_RESET_NAME match the
current definition data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
22067
[Channel %1: ] Tool management: tool change not possible since there is no tool
available in tool group %2
Parameters:
%1 = Channel number
%2 = String (identifier)
Definitions:
The desired tool change is not possible. The specified tool group does not contain a tool which is ready for use and
could be used for tool change. It is possible that all of the tools in question have been set to the 'Disabled' state by the
tool monitoring function.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
- Ensure that the specified tool group contains a tool that is ready for use when tool change is requested.
- This can be achieved, for example, by replacing disabled tools, or
- by releasing a disabled tool manually.
- Check whether the tool data are correctly defined. Have all intended tools in the group been defined with the specified
identifier and loaded?
Program
Clear alarm with the RESET key. Restart part program
Continuation: