Block %2 Illegal Cycle Alarm Number %3; Block %2 Wrong Starting Conditions For Contpron/Contdcon; Block %2 Wrong Array Dimension For Contpron/Contdcon - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the angle of shear in accordance with the geometrical conditions of the machine and workpiece system.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15700
[Channel %1: ] Block %2 illegal cycle alarm number %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cycle alarm number
Definitions:
A SETAL command has been programmed with a cycle alarm number smaller than 60 000 or greater than 67 999.
Alarm reaction of Siemens standard cycles:
Nos. 61 000 -61 999: Interpreter stop; delete with Reset
Nos. 62 000 - 62 999: Compensation block; delete with NC Start
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program alarm number in the SETAL instruction in the correct range.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15800
[Channel %1: ] Block %2 wrong starting conditions for CONTPRON/CONTDCON
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
There is an error in the start conditions for CONTPRON/CONDCON:
- G40 not active
- SPLINE or POLY active
- Unknown machining type programmed
- Transferred machining direction not defined
- Definition of LUDs in incorrect subroutine level
- Transferred circle coordinates
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15810
[Channel %1: ] Block %2 wrong array dimension for CONTPRON/CONTDCON
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The number of columns for the array created for CONTPRON/CONTDCON does not conform to the current program-
ming guide.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
216