Block %2 Invalid Base Frame Definition For Tool Carrier Offset; Toolholder Selection Error At Reset; Block %2 Illegal Interpolation Type With Movt - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Enter a valid fine correction value.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14155
[Channel %1: ] Block %2 invalid base frame definition for tool carrier offset
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If a tool carrier selection causes a change in the table offset, a valid base frame must be defined in order to store this
offset; for more information see machine data 20184 (TOCARR_BASE_FRAME_NUMBER).
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Change the NC program or machine data 20184 (TOCARR_BASE_FRAME_NUMBER).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14156
[Channel %1: ] Toolholder selection error at reset
Parameters:
%1 = Channel number
Definitions:
The settings in MD20110 $MC_RESET_MODE_MASK require that an active orientable toolholder is maintained after
the reset. This is done by deselecting the old orientable toolholder and then reselecting it with data that may have been
modified. If an error occurs during the reselection, this alarm is issued (as a warning) and then an attempt is made to
select the orientable toolholder in the initial setting. If this second attempt is successful, the reset cycle is continued
without any further alarms.
Typically, the alarm only occurs when the old orientable toolholder has been selected with TCOFR, and its axis direc-
tions have been changed in such a way before the reset that a setting suitable for the associated frame is no longer
possible. If there is another cause for the alarm, this results in an alarm also being issued when attempting to select
in the initial setting. This is then also displayed in plain text.
Reaction:
Alarm display.
Remedy:
Check the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14157
[Channel %1: ] Block %2 illegal interpolation type with MOVT
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Linear or spline interpolation must be active with MOVT (G0, G1, ASPLINE, BSPLINE, CSPLINE).
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
169

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents