15176
[Channel %1: ] Block %2 Program%3 may only be executed after Power ON
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File name
Definitions:
If an encrypted program is loaded to the NCK, an NCK reset (restart) must be performed afterwards, because internal
data for efficient processing of the encrypted program are preprocessed during NCK power-up. On calling an
encrypted NC program it has now been detected that these data do not exist or are obsolete compared to the current
version of the encrypted NC program.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Perform an NCK reset (restart).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15177
[Channel %1: ] Block %2 Error on preprocessing of program %3, error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File name
%4 = Error code
Definitions:
If an encrypted program is loaded to the NCK, an NCK reset (restart) must be performed afterwards, because internal
data for efficient processing of the encrypted program are preprocessed during NCK power-up. The following problem
has occurred:
Error code 1: Error on read-in of program %4
Error code 2: There is not enough DRAM memory available for storing the preprocessed data.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Error code 1: Encrypt and load program %4 again. Then perform an NCK reset (restart).
Error code 2: Increase system SL 710-740, 802D, 828D: $MN_MM_T_FILE_MEM_SIZE.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15180
[Channel %1: ] Block %2: Error on editing program %3 as INI/DEF file.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Definitions:
Errors were found when processing an initialization program (INI file), or a GUD or macro definition file (DEF file).
The error message which is then displayed refers to the program specified here.
Reaction:
Alarm display.
Remedy:
Correct the initialization program (INI file), or the GUD or macro definition file (DEF file).
In connection with Alarm 12380 or 12460, also change the memory configuration.
Program
Clear alarm with the Delete key or NC START.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Increase system SL 840 DI: $MN_MM_DRAM_FILE_MEM_SIZE.
Then perform an NCK reset (restart).