SINAMICS alarms
235211
<location>TM: Temperature alarm threshold channel 1 exceeded
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM120
Reaction:
NONE
Acknowledge:
NONE
Cause:
The temperature measured using the temperature sensing of the Terminal Module (TM) (r4105[0]) has exceeded the
threshold value to initiate this alarm (p4102[0]).
For PTC, the following applies:
- if r4101[0] > 1650 ohms, the temperature r4105[0] = 250 °C
- if r4101[0] <= 1650 ohms, the temperature r4105[0] = -50°C
Alarm value (r2124, interpret decimal):
Temperature value multiplied by 10 at the point of initiation.
Remedy:
See also: p4102 (TM120 temperature evaluation fault/alarm threshold)
235212
<location>TM: Temperature alarm threshold channel 2 exceeded
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM120
Reaction:
NONE
Acknowledge:
NONE
Cause:
The temperature measured using the temperature sensing of the Terminal Module 120 (TM120) (r4105[1]) has
exceeded the threshold value to initiate this alarm (p4102[2]).
For PTC, the following applies:
- if r4101[1] > 1650 ohms, the temperature r4105[1] = 250 °C
- if r4101[1] <= 1650 ohms, the temperature r4105[1] = -50°C
Alarm value (r2124, interpret decimal):
Temperature value multiplied by 10 at the point of initiation.
Remedy:
See also: p4102 (TM120 temperature evaluation fault/alarm threshold)
235213
<location>TM: Temperature alarm threshold channel 3 exceeded
Message value:
%1
Drive object:
AFE_SINUMERIK_828, BIC_SINUMERIK_828, SERVO_COMBI, SERVO_SINUMERIK828, SIC_COMBI,
SIC_SINUMERIK_828, TM120
Reaction:
NONE
Acknowledge:
NONE
Cause:
The temperature measured using the temperature sensing of the Terminal Module 120 (TM120) (r4105[2]) has
exceeded the threshold value to initiate this alarm (p4102[4]).
For PTC, the following applies:
- if r4101[2] > 1650 ohms, the temperature r4105[2] = 250 °C
- if r4101[2] <= 1650 ohms, the temperature r4105[2] = -50°C
Alarm value (r2124, interpret decimal):
Temperature value multiplied by 10 at the point of initiation.
Remedy:
See also: p4102 (TM120 temperature evaluation fault/alarm threshold)