NCK alarms
61234
[Channel %1: ] Block %2: ShopMill subroutine %4 cannot be executed, as not tested by
ShopMill
Parameters:
%1 = Channel number
%2 = Block number, label
%4 = Subroutine name
Definitions:
Before a ShopMill subroutine can be used, it has to be tested by ShopMill.
Alarm triggered by following cycle: E_HEAD.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The subroutine first has to be simulated in ShopMill or loaded into the ShopMill operating mode "Machine auto".
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61235
[Channel %1: ] Block %2: ShopTurn program %4 cannot be executed as not tested by
ShopTurn.
Parameters:
%1 = Channel number
%2 = Block number, label
%4 = Program name
Definitions:
Before a ShopTurn program can be executed, it has to be tested by ShopTurn.
Alarm triggered by following cycle: F_HEAD
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode "Machine auto".
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61236
[Channel %1: ] Block %2: ShopTurn subroutine %4 cannot be executed as not tested
by ShopTurn.
Parameters:
%1 = Channel number
%2 = Block number, label
%4 = Subroutine name
Definitions:
Before a ShopTurn subroutine can be used, it has to be tested by ShopTurn.
Alarm triggered by following cycle: F_HEAD.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode "Machine auto".
Program
Clear alarm with the RESET key. Restart part program
Continuation:
412
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0