NCK alarms
61226
[Channel %1: ] Block %2: Inclinable head cannot be exchanged
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameter "Swivel data block" is set to "No". In spite of this, an attempt has been made to change the swivel head.
Alarm triggered by following functions: E_TCARR, F_TCARR.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Set the parameter "Swivel data block" in the setup screen "Rotary axes" to "Automatic" or "Manual".
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61228
[Channel %1: ] Block %2: Retraction plane for swiveling with swivel head not reached
due to software limit switches
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggered by the following cycles: F_SP_RPB, E_SP_RP
Retraction plane not reached!
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct retraction plane
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61229
[Channel %1: ] Block %2: The external retraction plane must be greater than the
internal retraction plane
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggered by the following cycles: F_SP_RP
The external retraction plane must be greater than the internal retraction plane.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct the retraction planes.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61230
[Channel %1: ] Block %2: Tool probe diameter too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool probe has not been calibrated correctly.
Alarm triggered by following cycles: E_MT_CAL, E_MT_RAD, E_MT_LEN.