Action %2 Alnx Not Possible Due To Program Test; Action %2 Alnx Aborted Due To Active Gear Change; Action %2 Alnx Rejected Due To Active Gear Change; Action %2 Alnx Wait For Gear Change - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Alarm display.
Remedy:
Abort program with the RESET key.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16937
[Channel %1: ] Action %2<ALNX> not possible due to program test
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
This action is not allowed as program test is currently active.
Example: It is not permissible to activate block search via program test (PI service _N_FINDBL with mode parameter
5) when program test is active.
Reaction:
Alarm display.
Remedy:
Deactivate program test.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16938
[Channel %1: ] Action %2<ALNX> aborted due to active gear change
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Reorganization events are, among others, subprogram abort, delete distance-to- go and interrupts, axis exchange,
exiting the correction state. These events wait for the end of a gear change. However, the maximum waiting period
has elapsed.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Program must be aborted with Reset and, if necessary, MD10192 $MN_GEAR_CHANGE_WAIT_TIME must be
increased.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16939
[Channel %1: ] Action %2<ALNX> rejected due to active gear change
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Reorganization events that are possible in Stop state, e.g mode change, are waiting for the end of the gear change.
However, the maximum waiting period has elapsed.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Repeat action or increase MD10192 $MN_GEAR_CHANGE_WAIT_TIME.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16940
[Channel %1: ] Action %2<ALNX> wait for gear change
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Reorganization events are waiting for the end of a gear change. The alarm is displayed during the waiting period.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
257

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d