Remedy:
Please inform the authorized personnel/service department.
- Erroneous PLC communication: Correct the PLC program.
- It is possible to release NCK with the PLC command 7 from the wait condition.
This aborts the waiting command.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
6407
[Channel %1: ] Tool %2 cannot be placed in magazine %3 on location %4. Invalid
definition of magazine!
Parameters:
%1 = Channel ID
%2 = String (identifier)
%3 = Magazine number
%4 = Magazine location number
Definitions:
A tool change request or a verification request was issued to put the tool in a location which does not satisfy the pre-
requisites for filling.
The following causes for the error are possible:
- Location is blocked or not free!
- Tool type does not match the location type!
- Tool possibly too large, adjacent locations are not free!
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Check whether the magazine data are correctly defined (especially the location type).
- Check whether the tool data are correctly defined (especially the location type).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
6410

[TO unit %1: ] Tool %2 has reached its prewarning limit with D = %4

Parameters:
%1 = TO unit
%2 = Tool identifier (name)
%3 = -Not used-
%4 = D number
Definitions:
Tool monitoring: This message informs that the specified D offset has reached its prewarning limit for a time-, quantity-
or wear-monitored tool. If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
If the function additive offset is being used, additive offset monitoring may be active instead of tool wear monitoring.
The actual type of tool monitoring is a tool property (see $TC_TP9). If replacement tools are not being used, the duplo
number specified has no meaning. The alarm is triggered through the HMI or PLC (=OPI interface). The channel con-
text is not defined. The TO unit was specified for this reason (see MD28085 $MC_MM_LINK_TOA_UNIT).
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program
Clear alarm with the Delete key or NC START.
Continuation: