NCK alarms
Definitions:
The tool radius compensation of the working area limitation of the stated axis is not taken into account.
Reason: No tool is active.
The alarm is reported in JOG mode.
Reaction:
Alarm display.
Remedy:
The tool radius compensation for working area limitations in JOG mode cannot be taken into account wihout an active
tool.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10650
[Channel %1: ] Axis %2 incorrect gantry machine data, error code %3
Parameters:
%1 = Channel number
%2 = Axis
%3 = Error no.
Definitions:
An incorrect value was entered in the gantry-specific axial machine data. Further information can be derived from the
error number.
- Error no. = 1 => either an incorrect gantry unit has been entered or the designation of the following axis is incorrect.
- Error no. = 2 => master axis has been specified more than once.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Correct the machine data:
MD37100 $MA_GANTRY_AXIS_TYPE
0: No gantry axis 1: Master axis grouping 1 11: Slave axis grouping 1 2: Master axis grouping 2 12: Slave axis grouping
2 3: Master axis grouping 3 13: Slave axis grouping 3
Program
Switch control OFF - ON.
Continuation:
10651
[Channel %1: ] Gantry configuration error. Error code %2
Parameters:
%1 = Channel number
%2 = Reason
Definitions:
The gantry configuration set in the machine data is erroneous. Gantry unit and reason for objection can be found in
the transfer parameter.
The transfer parameter is made up as follows.
- %2 = error designation + gantry unit (XX).
- %2 = 10XX => no master axis declared
- %2 = 20XX => no slave axis declared
- %2 = 30XX => different contents in MD30550 $MA_AXCONF_ASSIGN_MASTER_CHAN slave axis and master axis
- %2 = 40XX => different channel or NCU assignment of the gantry axes
- %2 = 50XX => no slave axis declared in this channel
- 2% = 60XX => different channel assignment of the master axis
- %2 = 10000 => error: slave axis is geometry axis
- %2 = 11000 => error: competing positioning axis as slave axis
- %2 = 12000 => error: compile cycle axis as slave axis
- %2 = 13000 => error: gantry axis is spindle
- %2 = 14000 => error: gantry axis is Hirth geared
e.g. error code 1001 = no master axis declared, gantry unit 1.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
78