NCK alarms
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61306
[Channel %1: ] Block %2: Permissible measuring difference exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE982, CYCLE994.
Remedy:
- Check setpoint value and parameter _TDIF
61307
[Channel %1: ] Block %2: Incorrect measuring variant
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
- The value of parameter _MVAR is impermissible.
61308
[Channel %1: ] Block %2: Check measuring path
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
A traversing path for measuring is generated with a size specified by parameter _FA (in 840D) or DFA (in 840D sl). It
describes the maximum distance before and after the expected switching position (workpiece edge) and must have a
value greater than 0.
For 840D:
- Check parameter _FA
For 840D sl:
- Check parameter DFA
61309
[Channel %1: ] Block %2: Check probe type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Probe type: 3D probe inactive.
This alarm is generated by all cycles except CYCLE971, CYCLE972, CYCLE982.
Remedy:
The probe has to be of the "3D probe" type in the tool management.
Tool type of the workpiece probe in the TO memory is impermissible.
For CYCLE971: no permissible tool probe type entered in _TP[x,8], or check
the permissible working plane G17...G19 in the case of tool type "Wheel".
61310
[Channel %1: ] Block %2: Scale factor is active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Scale factor = scaling is active.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Switch off the active scale factor in the program. Measuring is not possible with an active scale factor.