Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17260
[Channel %1: ] Block %2 illegal magazine location definition
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
This alarm occurs if an attempt is made to change a magazine location data which would subsequently damage data
consistency irreparably or lead to a conflicting definition.
Example: If parameter $TC_MPP1 (= type of location) is written with 'spindle/toolholder location',
this may conflict with the limiting MD18075 $MN_MM_NUM_TOOLHOLDERS.
The remedy is then either - if permitted by the control model - to increase the value of MD18075
$MN_MM_NUM_TOOLHOLDERS
or to correct the magazine definition.
It is not permitted to assign one tool to two different magazine locations at the same time. Neither may a tool be part
of a multitool and in a magazine location at the same time.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17262
[Channel %1: ] Block %2 illegal tool adapter operation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If an attempt is made to define or cancel a tool adapter assignment with reference to a magazine location and this
magazine location already has another tool adapter and/or a tool is located in the adapter or - when canceling an
assignment - a tool is still at the location, this alarm will appear. If machine data MD18108
$MN_MM_NUM_SUMCORR has the value -1, adapters cannot be generated by a write operation to an adapter which
is not already defined. While the machine data has this value, you can only write adapter data to adapters which have
already been (automatically) assigned to magazine locations.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Assign max. one adapter to a magazine location.
- The magazine location must not contain a tool.
- MD18108 $MN_MM_NUM_SUMCORR has value -1: If an alarm occurs when writing one of the system variables
$TC_ADPTx (x=1,2,3,T), the write operation must be modified such that only adapter data which are already associ-
ated with the magazine locations are written.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17270
[Channel %1: ] Block %2 call-by-reference: illegal variable
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Machine data and system variables must not be transferred as call-by-reference parameters.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
281