Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16690
[Channel %1: ] Block %2 following axis/spindle %3 changing the reference system %4
is not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reference system
Definitions:
An attempt was made to change the reference system with generic coupling active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part programm.
End coupling and reactivate with desired reference system.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16691
[Channel %1: ] Block %2 following axis/spindle %3 changing the reference system %4
is not possible.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Reference system
Definitions:
An attempt was made to change the reference system with generic coupling active.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part programm.
End coupling and reactivate with desired reference system.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16692
[Channel %1: ] Block %2 following axis/spindle %3 maximum number of couplings in
the block %4 has been exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Maximum number of couplings
Definitions:
The maximum number of generic couplings in the block has been exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Reduce the number of generic couplings programmed in the block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
233