61549
[Channel %1: ] Block %2: Incorrect dresser type selected
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycles: CYCLE402, CYCLE421, CYCLE422, CYCLE423,
CYCLE424
Remedy:
Check dresser type on input
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61555
[Channel %1: ] Block %2: Diameter of grinding wheel ==0, GWPS cannot be calculated
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy:
Check diameter
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61556
[Channel %1: ] Block %2: Impossible chamfer and radius of left edge of wheel
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE432
Remedy:
Check values in grinding wheel data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61557
[Channel %1: ] Block %2: Impossible chamfer and radius of right edge of wheel
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE432
Remedy:
Check values in grinding wheel data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61558
[Channel %1: ] Block %2: Chamfer / radius + shoulder height are less than the
retraction height of the left edge of the grinding wheel
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following grinding cycle: CYCLE432
Remedy:
Check values in grinding wheel data
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
461