Block %2 No Stop Required - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16755
[Channel %1: ] Block %2 no stop required
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No Stop is needed for the programmed function. A Stop is necessary after SPOSA or after M5 if the next block is to
be loaded only after a spindle stop.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Do not write instruction.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16757
[Channel %1: ] Block %2 for following spindle %3 coupling as leading spindle/axis
already existing
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Following spindle number
Definitions:
A coupling has been switched on in which the following spindle/axis has already been active as leading spindle/axis
in another coupling. Chained couplings cannot be processed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check in the parts program whether the following spindle/axis is already active as leading spindle/axis in another cou-
pling.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16758
[Channel %1: ] Block %2 for leading spindle %3 coupling as following spindle/axis
already existing
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Leading spindle number
Definitions:
A coupling has been switched on in which the leading spindle/axis has already been active as following spindle/axis
in another coupling. Chained couplings cannot be processed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check in the parts program whether the leading spindle/axis is already active as following spindle/axis in another cou-
pling.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
239

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents