NCK alarms
17193
[Channel %1: ] Block %2 the active tool is no longer on toolholder no./spindle no. %3,
program %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Toolholder no., spindle no.
%4 = Program name
Definitions:
The tool at the specified toolholder/spindle at which the last tool change was carried out as master toolholder or master
spindle, has been replaced.
Example:
N10 SETHTH(1)
N20 T="Wz1" ; Tool change at master toolholder 1
N30 SETMTH(2)
N40 T1="Wz2" ; Toolholder 1 is only a secondary toolholder.
Changing the tool does not result in correction deselection.
N50 D5; New correction selection. At present, there is no active tool which D can refer to, i.e. D5 refers to T no. = 0,
which results in zero correction.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
- Modify program:
- Set desired spindle as master spindle or toolholder as master toolholder.
- Then, if required, reset master spindle or master toolholder.
Program
Clear alarm with the Delete key or NC START.
Continuation:
17194
[Channel %1: ] Block %2 no suitable tool found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- An attempt was made to access a tool which has not been defined.
- The specified tool does not permit access.
- A tool with the desired properties is not available.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check access to tool:
- Are the parameters of the command correctly programmed?
- Does the status of the tool prevent access?
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17195
[Channel %1: ] block %2 illegal tool holder number %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Tool holder number
Definitions:
In the displayed block, a tool holder that is not defined is accessed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check the programming of the tool holder in the NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: