User interrupt ASUP /INTERRUPT/ No. 10
Definitions:
Execute an "ASUB" user interrupt.
(VDI signal, ASUB interface, digital-analog interface)
Alarms can be switched on by machine data "HW_DEBUG_MASK" (for test purposes only).
Not permitted if:
1. The channel is active on account of block search or loading machine data
2. The channel has stopped, and the ASUB "ASUP_START_MASK" has to be started,
and the current block cannot be reorganized.
3. Reference point approach has not yet been made
Possible actions:
1. Wait until block search or loading machine data has finished,
or cancel the program with the Reset button.
2. Activate block change until NC block can be reorganized
3. Execute reference point approach, or this status can be
User interrupt at end of block /INTERRUPTBLSYNC/ No. 12
Definitions:
Execute an "ASUB" user interrupt at the block boundary.
(VDI signal, ASUB interface, digital-analog interface)
as INTERRUPT
User interrupt in manual mode /INTERRUPT_TOPROG_NOREPOS/ No. 85
Definitions:
Activate a user interrupt "ASUB" in a manual mode (JOG, REF,...).
(VDI signal, ASUB interface, digital-analog interface)
See INTERRUPT
User interrupt with rapid retract /INTERRUPTFASTLIFTOFF/ No. 11
Definitions:
Execute an "ASUB" user interrupt with fast retraction.
(VDI signal, ASUB interface, digital-analog interface)
as INTERRUPT
User PLC version file /PLCVERSION/ No. 94
Definitions:
Write user PLC version in version file
Should not occur in any alarm
Waiting for acknowledgment /MMCCMD/ No. 60
Definitions:
Wait until acknowledgement arrives from MMC (NC block, MMC_CMD)
Should not occur in any alarm
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
ignored by means of machine data "ASUP_START_MASK".
List of actions