NCK alarms
22297
[Channel %1: ] Spindle %2 FC18 function not possible (cause: error code %3)
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Error code
Definitions:
The function request by PLC via FC18 interface could not be executed. The cause is specified by the error code.
Error codes:
- Error code 1 : internal use
- Error code 2 : internal use
- Error code 3 : internal use
- Error code 4 : internal use
- Error code 5 : Switchover to command axis not possible
- Error code 6 : Switchover to PLC axis not possible
- Error code 20 : internal use
- Error code 21 : internal use
- Error code 22 : internal use
- Error code 23 : MD 30132 IS_VIRTUAL_AX has been set
- Error code 50 : internal use
- Error code 51 : internal use
- Error code 70 : internal use
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy conflict.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22320
[Channel %1: ] Block %2 PUTFTOCF command could not be transferred
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The cyclic transfer of the PUTFTOCF data block (fine tool compensation) could not be performed because the transfer
area is already occupied.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check the part program, in particular with regard to the other channels. Is a data block being transferred by another
channel?
Program
Clear alarm with the RESET key. Restart part program
Continuation:
22321
[Channel %1: ] Axis %2 PRESET not allowed during traverse motion
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A preset command was sent from the HMI or PLC while an axis was traveling in JOG mode.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Wait until the axis is stationary.
Program
Clear alarm with the Delete key or NC START.
Continuation: