Block %2: Absolute Reference Missing; Block %2: %]Wrong Tool Type; Block %2: Circle Radius Too Small; Block %2: No Pitch Programmed - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61211
[Channel %1: ] Block %2: Absolute reference missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An incremental indication was made, but the absolute reference is unknown.
Alarm triggered by following cycles: E_MI_CON, E_MI_PL, E_PI_CIR, E_PI_REC, E_PO_CIR, E_PO_REC,
E_PS_CIR, E_PS_HIN, E_PS_MRX, E_PS_POL, E_PS_SEQ, E_PS_XYA, E_SL_CIR, E_SL_LON, F_PS_CIR,
F_PS_MRX, F_PS_SEQ
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program an absolute position prior to using incremental indications.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61212
%[[Channel %1: ] Block %2: %]Wrong tool type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool type is not suitable for machining.
Alarm triggered by following cycles: CYCLE63, CYCLE64, CYCLE92, CYCLE951, CYCLE952, E_DR, E_DR_O1,
E_DR_PEC, E_DR_SIN, E_MI_TXT, F_DR, F_DR_PEC, F_DR_SIN, F_DRILL, F_DRILLC, F_DRILLD, F_DRM_DR,
F_DRM_PE, F_DRM_SI, F_GROOV, F_MI_TXT, F_MT_LEN, F_PARTOF, F_ROU_Z, F_ROUGH, F_SP_EF,
F_TAP, F_TR_CON, F_UCUT_T
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select a new tool type.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61213
[Channel %1: ] Block %2: Circle radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed circle radius is too small.
Alarm triggered by following cycles: CYCLE77, E_CR_HEL, E_PI_CIR, E_PO_CIR, E_PO_REC, F_PI_CIR,
F_PO_CIR, F_PO_REC
Remedy:
Correct the circle radius, center point or end point.
61214
[Channel %1: ] Block %2: No pitch programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No thread/helical pitch has been entered.
Alarm triggered by following cycles: E_CR_HEL, E_PO_CIR, E_PO_REC, F_PO_CIR, F_PO_REC.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program a pitch.
406
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents