Block %2: No Work Offset Entered For Main Spindle; Block %2: No Work Offset Entered For Counterspindle; Block %2: Probe Defective - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the retraction plane in absolute terms.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61298
[Channel %1: ] Block %2: No work offset entered for main spindle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggered by the following cycles: F_SUB_SP
No work offset has been specified for the main spindle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify a work offset for the main spindle in the program header or under Settings.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61299
[Channel %1: ] Block %2: No work offset entered for counterspindle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggered by the following cycles: F_SUB_SP
No work offset has been entered for the counterspindle.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify a work offset for the counterspindle in the program header or under Settings.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61300
[Channel %1: ] Block %2: Probe defective
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
430