Clear alarm with the RESET key. Restart part program
Continuation:
12660
[Channel %1: ] Block %2 motion synchronous action: variable %3 reserved formotion
synchronous actions and technology cycles
Parameters:
%1 = Channel number
%2 = Block number
%3 = Variable name
Definitions:
The displayed variable may only be used in motion synchronous actions or in technology cycles. For example, '$R1'
may only be used in motion synchronous actions. In standard part programs R parameters are programmed with R1.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12661
[Channel %1: ] Block %2 technology cycle %3: no further subprogram call possible
Parameters:
%1 = Channel number
%2 = Block number
%3 = Name of the technology cycle call
Definitions:
In a technology cycle it is not possible to call a subroutine or another technology cycle.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12700
[Channel %1: ] Block %2 contour definition programming not allowed as modal sub-
programis active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the external language mode, a block is programmed with contour definition and a modal cycle is active at the same
time. Because of unclear address assignment (e.g. R = radius for contour definition or return plane for drilling cycle)
contour definition programming must not be used when a modal cycle is active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms