Block %2 Maximum Subroutine Level Exceeded; Block %2 Number Of Subroutine Passes Invalid; Selected Program %3 Not Available Or Will Be Edited - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Ensure that the subroutine (alarm parameter %3)
- is available in the parts program memory
- has been released and is not being edited
- is available in the search path if not being called via an absolute path name.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14012
[Channel %1: ] Block %2 maximum subroutine level exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The maximum nesting depth of 8 program levels has been exceeded.
Subroutines can be called from the main program, and these in turn may have a nesting depth of 7.
In interrupt routines the maximum number of levels is 4!
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify the machining program so that the nesting depth is reduced, e.g. using the editor copy a subroutine of the next
nesting level into the calling program and remove the call for this subroutine. This reduces the nesting depth by one
program level.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14013
[Channel %1: ] Block %2 number of subroutine passes invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a subroutine call the programmed number of passes P is zero or negative.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program number of passes between 1 and 9 999.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14014
[Channel %1: ] Selected program %3 not available or will be edited
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
The selected parts program is not in the NCK memory or the access authorization for the program selection is from a
higher level than the current control status.
During creation, this program received the protection level of the NC control which was active at the time.
In SW 5 or higher a program edited on HMI can no longer be started with NC Start.
The alarm will also be issued, if a file other than the specified definition file has been selected for the GUD or macro
definition.
Reaction:
Alarm display.
Remedy:
Reload the program in the NCK memory or check and correct the name of the directory (workpiece overview) and the
program (program overview) and reselect.
Alarms