14180
[Channel %1: ] Block %2 H number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = H number of ISO mode
Definitions:
The specified H number is not assigned to a tool (ISO_M).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14181
[Channel %1: ] Block %2 ISO tool offset %3 not present
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Offset number
Definitions:
Only relevant in ISO2 and ISO3 modes:
When selecting the tool offset with H or D:
Only tool offsets 1 - 98 are permissible in ISO2 and ISO3 modes.
Exception: The structured cutting edge D1 of the active tool can also be selected with H99 in ISO2 mode or with the
offset component in the tool selection in ISO3 mode.
When writing the tool offset with G10:
Only tool offsets 1 - 98 are permissible in ISO2 and ISO3 modes.
Tool offset H99 can only be written in Siemens programming mode (G290) with $TC_DPx[y,z]=.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Correct NC block and select a permissible tool offset in the range 1 to 98.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14182
[Channel %1: ] Block %2 different values under H and D addresses
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only relevant in ISO2 mode:
Tool length and tool radius are programmed with H and D. The programming leads to contradictory offset numbers in
the coupled offset memories.
172
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents