List of actions
Program stop /STOPPROG/ No. 30
Definitions:
Execute a program stop (NC block M0)
Should not occur in any alarm
Rapid retract /FASTLIFTOFF/ No. 13
Definitions:
Execute a fast retraction
Should not occur in any alarm
Reorganize after block preparation /STOPATIPOBUF_EMPTY_ALARM_REORG/ No. 72
Definitions:
Stop at end of block preparation (alarm)
followed by reorganization of the block preparation.
Not permitted if:
1. The nesting depth is too great
Possible actions:
1. Wait until previous ASUB has finished or cancel program
Reorganize block preparation /PURE_REORG/ No. 84
Definitions:
Reorganize block execution
Should not occur in any alarm
Reset /RESET/ No. 2
Definitions:
Execute reset (VDI signal reset, mode group reset or after power on).
Should not occur in any alarm
Reset due to end of program /PROG_END/ No. 4
Definitions:
Execute reset. Program end has been detected (NC block M30).
Should not occur in any alarm
Reset Init blocks /RESET_INITBLOCK/ No. 3
Definitions:
Activate reset INIT blocks.
(Is initiated by the VDI signal reset)
Should not occur in any alarm
Retraction movement and stop /RETREAT_MOVE_THREAD/ No. 76
Definitions:
Retraction motion with G33 and Stop
Should not occur in any alarm
924
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0