Block %2 Incorrect Index Type For %3; Block %2 Identifier %3 Too Long; Block %2 Specified Index Is Invalid - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

12410
[Channel %1: ] Block %2 incorrect index type for %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
In assigning a value to an element of an array variable, the array index was specified in a way that is not allowed.
Only the following are allowed as array index (in square brackets):
- Axis identifier, provided the array variable was defined as data type FRAME.
- Integer values for all other data types.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block. Correct indices of the array element with respect to variable definition
or define the array variable differently.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12420
[Channel %1: ] Block %2 identifier %3 too long
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
-
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block. The symbol to be created or the target of program jumps (label) must
conform to the system specifications, that means the name must begin with 2 letters (but the 1st sign must not be "$")
and may be up to a maximum of 32 characters.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12430
[Channel %1: ] Block %2 specified index is invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In specifying an array index (in the array definition) an index was used that is outside the permissible range.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block. Specify array index within the permissible range. Value range per array
dimension: 1 - 32 767.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
123