No Center Point Specified For Circle; Specified Starting Point Programmed Incorrectly; Helix Radius Too Small - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Remedy:
- Check parameter for specified starting point,
- for G17: XS, YS
- for G18: ZS, XS
- for G19: YS, ZS
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61939
%[[Channel %1: ] Block %2: %]No center point specified for circle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check contour programming, particularly circular-path programming
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61940
%[[Channel %1: ] Block %2: %]Specified starting point programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Correct specified starting point
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61941
%[[Channel %1: ] Block %2: %]Helix radius too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE63
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Increase helix radius
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms