Block %2 Motion Synchronous Action: Nesting Depth Exceeded; Block %2 Motion Synchronous Action: Command Not Executable; Block %2 Motion Synchronous Action: Internal Error %3 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Correct error in expression.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
20146
[Channel %1: ] Block %2 motion synchronous action: nesting depth exceeded
Parameters:
%1 = Channel number
%2 = Block number
Definitions:
For calculating arithmetic expressions in motion synchronous blocks, an operand stack with a fixed set size is used.
With very complex expressions, this stack can overflow.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Correct error in expression.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
20147
[Channel %1: ] Block %2 motion synchronous action: command not executable
Parameters:
%1 = Channel number
%2 = Block number
Definitions:
One of the commands for the synchronous action block cannot be executed, e.g. it is not possible to perform a Reset
to the synchronous action.
Measurement level 2
- Embargo version does not allow measurement from a synchronized action
- MEASA was programmed in a synchronized action
- Measurement is already active
- Programming error (see alarm 21701)
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change synchronous action.
Measurement level 2
Execute the measurement task from an NC program first, in order to improve the error diagnostics. Only include it in
the synchronized action when the first error-free run has been performed.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
20148
[Channel %1: ] Block %2 motion synchronous action: internal error %3
Parameters:
%1 = Channel number
%2 = Block number
%3 = Error code
Definitions:
An internal error has occurred during processing of a synchronous action. The error code is for diagnostics purposes.
Please make a note and contact the manufacturer.
314
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents