Block %2 H And D Addresses Must Be Programmed After Siemens Offset; Block %2 G44 Is Not Possible With Tool Offset H99; Block %2 D Number %3 Is Not Defined - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Correct NC block. Only program H or D, or program the same value under H and D addresses.
Set MD10890 $MN_EXTERN_TOOLPROG_MODE, Bit6=1. Different values can then be programmed in the H and
D addresses.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14183
[Channel %1: ] Block %2 H and D addresses must be programmed after Siemens offset
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only relevant in ISO2 mode:
A tool offset in Siemens mode with D>1 is active and an ISO2 command G43, G44,G49 is applied. Furthermore an
ISO offset with H0 - H99 or D0-D98 must be selected.
The alarm is also output, if MD10890 $MN_EXTERN_TOOLPROG_MODE, bit6=1:
If the Siemens offset memory with H99 or a cutting edge has been selected in Siemens mode, both the tool length and
tool radius offsets will have to be reselected the next time the ISO offset memory is selected.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Correct NC block.
Program H and/or D address in the block.
If MD10890 $MN_EXTERN_TOOLPROG_MODE, bit6=0, only H or D address must be programmed.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14184
[Channel %1: ] Block %2 G44 is not possible with tool offset H99
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Only relevant in ISO2 mode:
The structured D number D1 of the active tool has been selected with H99. These offset values cannot be calculated
negatively with G44.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Correct NC block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14185
[Channel %1: ] Block %2 D number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = D number of ISO mode
Definitions:
The specified D number is not assigned to a tool (language mode ISO_M).
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d