Block %2: Number Of Holes Is Zero; Block %2: Contour Violation Of Slots; Block %2: Milling Cutter Radius Too Large; Block %2: Number Of Or Distance Between Circular Elements - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

61103
[Channel %1: ] Block %2: Number of holes is zero
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No value for the number of holes has been programmed. Alarm triggered by following cycles: HOLES1, HOLES2.
Remedy:
Check parameter NUM.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61104
[Channel %1: ] Block %2: Contour violation of slots
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Incorrect parameterization of the milling pattern in the parameters which define the position of the slots/elongated
holes on the circle and their form. Alarm triggered by following cycles: SLOT1, SLOT2, LONGHOLE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61105
[Channel %1: ] Block %2: Milling cutter radius too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The diameter of the cutter used is too large for the form to be machined. Alarm triggered by following cycles: SLOT1,
SLOT2, POCKET1 to POCKET4, LONGHOLE, CYCLE90.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Either a tool with a smaller radius has to be used or the contour must be modified.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61106
[Channel %1: ] Block %2: Number of or distance between circular elements
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Incorrect parameterization of NUM or INDA. The layout of the circle elements within a full circle is not possible. Alarm
triggered by following cycles: HOLES2, LONGHOLE, SLOT1, SLOT2.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct parameterization.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
385

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d