Block %2: %]Machining Plane Wrongly Programmed; Machining Plane On Cycle Call Differs From The One In Position Pattern; Block %2: Residual Material Remains Stationary, Reduce Plane Infeed; Block %2: Centering Diameter Or Tool Parameter Are Incorrect - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61157
%[[Channel %1: ] Block %2: %]Reference point wrongly programmed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE63, CYCLE64, CYCLE899
Remedy:
Check reference point in screen form, input only -X, centred or +X
61158
%[[Channel %1: ] Block %2: %]Machining plane wrongly programmed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE63, CYCLE64, CYCLE899, CYCLE952
Remedy:
Check machining plane (G17, G18 or G19)
61159
[Channel %1: ] Block %2: Machining plane on cycle call differs from the one in the
position pattern
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE899
Remedy:
Adjust the machining plane on cycle call to the machining plane in the position pattern.
61160
[Channel %1: ] Block %2: Residual material remains stationary, reduce plane infeed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE899
Remedy:
Reduce plane infeed or slot width, or use milling cutter with larger diameter
61161
[Channel %1: ] Block %2: Centering diameter or tool parameter (diameter, tip angle) are
incorrect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE81
Remedy:
- Diameter of centering with tip angle of active tool not possible
- Entered workpiece diameter, tool diameter or tip angle of tool incorrect
- Diameter of tool only has to be entered if centering is to be on workpiece diameter.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61162
[Channel %1: ] Block %2: Tool parameter diameter or tip angle incorrect
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggered by the following cycle: CYCLE81
Remedy:
- The tool parameter diameter or tip angle must be greater than zero
- Tip angle must be less than 180°
396
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents