Block %2 T No.= %3, D No.= %4 Not Existing; Block %2 Illegal Sum Correction Number; Block %2 H Number Already Available In T No.= %3, D No.= %4 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check tool call in the NC parts program:
- Correct tool correction number D programmed? If no D number is specified with the tool change command, then the
D number set by MD20270 $MC_CUTTING_EDGE_DEFAULT will be active automatically. It is D1 by default.
- Tool parameters (tool type, length,...) defined? The dimensions of the tool edge must have been entered previously
either through the operator panel or through a tool data file in NCK.
Description of the system variables $TC_DPx[t, d] as included in a tool data file.
x ... Correction parameter number P
t ... Associated tool number T
d ... Tool correction number D
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17181
[Channel %1: ] Block %2 T no.= %3, D no.= %4 not existing
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number
%4 = D number
Definitions:
A programmed D number was not recognized by the NC. By default, the D number refers to the specified T number.
If the flat D number function is active, T= 1 is output.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
If the program is incorrect, remedy the error with a correction block and continue the program.
If the data block is missing, download a data block for the specified T/D values onto the NCK (via HMI with overstore)
and continue the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17182
[Channel %1: ] Block %2 illegal sum correction number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt was made to access a non-defined total offset of the current tool edge.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Access the total offset memory with $TC_SCP*, $TC_ECP*, check the total offset selection DLx or tool selection Ty
or offset selection Dz.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17183
[Channel %1: ] Block %2 H number already available in T no.= %3, D no.= %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number
%4 = D number
Definitions:
Each H number (except for H=0) must be assigned in a TO unit only once. The indicated edge already has the H num-
ber. If the H number shall be assigned more than once, MD10890 $MN_EXTERN_TOOLPROG_MODE, bit 3 must be
set = 1.