Profinet - Io I/O Fault: Log. Addr. %1 Bus/Station: %2; Plc Toolman: Missing Table In Db9900; Plc Toolman: Spindle Or Load Location Invalid; Plc Maintenance Planner: Error In Db 9903 Or 9904 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

PLC alarms
400015

Profinet - IO I/O fault: log. addr. %1 bus/station: %2

Definitions:
The PLC-AWP is using I/O addresses which are not available.
%1Logical I/O address
%2Bus number/station number
Causes of error:
Bus peripheral has no voltage
Bus address set incorrectly
Bus connection faulty
Active MD 11240 (SDB configuration) is set incorrectly
Reaction:
PLC Stop
Remedy:
Rectify the error using the error cause
Program
Switch control OFF - ON.
Continuation:
400017

PLC TOOLMAN: missing table in DB9900

Definitions:
The PLC TOOLMAN cannot find one of the tables 9900, 9901 or 9902.
Reaction:
PLC Stop
Remedy:
Create the missing table(s).
Program
Switch control OFF - ON.
Continuation:
400018

PLC TOOLMAN: Spindle or load location invalid

Definitions:
The PLC TOOLMAN does not know the specified spindle or load location number.
Reaction:
PLC Stop
Remedy:
Specify the correct number.
Program
Switch control OFF - ON.
Continuation:
400019

PLC maintenance planner: Error in DB 9903 or 9904

Definitions:
PLC maintenance planner: DBs 9903 and 9904 must be present and must have the same length.
Reaction:
PLC Stop
Remedy:
Create block(s) correctly.
Program
Switch control OFF - ON.
Continuation:
400020
PLC mainentance request %1 : Initial data not plausible
Definitions:
Redefine the initial data in accordance with the documentation.
Error causes:
Too many alarms for the interval length
Time of first alarm too late
Time of first alarm greater than interval
Reaction:
Alarm display.
Remedy:
Specify correct initital data according to the documentation.
Program
Clear alarm with the Delete key or NC START.
Continuation:
906
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents