Workpiece counter: overflow in table of monitored cutting edges.

Definitions:
No more cutting edges can be entered in the piece counter table.
As many cutting edges can be noted for the workpiece counter as are possible in total in the NCK.
This means that if for each tool each cutting edge in each TO unit is used precisely once for a workpiece then the limit
is reached.
If several workpieces are made on several toolholders/spindles simultaneously, it is possible to note
MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA cutting edges for the workpiece counter for all of the work-
pieces.
If this alarm occurs, it means that cutting edges used subsequently are no longer quantity monitored until the table has
been emptied again, e.g. by means of the NC language command SETPIECE or by the relevant job from HMI, PLC
(PI service).
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Was decrementing of the piece counter forgotten? Then program SETPIECE in the part program, or add the correct
command in the PLC program.
- If the part program/PLC program is correct, then more memory should be set for tool cutting edges via the MD18100
$MN_MM_NUM_CUTTING_EDGES_IN_TOA (can only be performed with the necessary access rights!).
Program
Clear alarm with the Delete key or NC START.
Continuation:
6431
[Channel %1: ] Block %2 Function not allowed. Tool management/monitoring is not
active.
Parameters:
%1 = Channel ID
%2 = Block number, label
Definitions:
Occurs when a data management function is called which is not available because ToolMan is deactivated. For exam-
ple, the language commands GETT, SETPIECE, GETSELT, NEWT, DELT.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Please inform the authorized personnel/service department.
- Make sure of how the NC is supposed to be configured! Is tool management or tool monitoring needed but not acti-
vated?
- Are you using a part program that is meant for a numerical control with tool management/tool monitoring? It is not
possible to start this program on the numerical control without tool management/tool monitoring. Either run the part
program on the appropriate NC control or edit the part program.
- Activate tool management/tool monitoring by setting the appropriate machine data. See
MD18080$MN_MM_TOOL_MANAGEMENT_MASK, MD20310$MC_TOOL_MANAGEMENT_MASK
- Check whether the required option is set accordingly.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
6432

Function not executable. No tool assigned to tool holder/spindle

Parameters:
%1 = Channel ID
Definitions:
When an attempt is made to perform an operation that requires a tool to be located on the spindle. This can be the
quantity monitoring function, for example.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Select another function, another toolholder/spindle, position tool on toolholder/spindle.
Program
Clear alarm with the Delete key or NC START.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0