NCK alarms
10: Error in internal structure of the protection zones.
11: Other, not further specified errors.
12: The number of protection zones simultaneously active exceeds the maximum number (channel-specific machine
data).
13,14: Contour element for protection zones cannot be created.
15,16: No more memory space for the protection zones.
17: No more memory space for the contour elements.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
If the alarm is output on ramp-up (2nd parameter: "INIT" instead of block number), "Channel not ready to operate" will
be set.
Remedy:
Please inform the authorized personnel/service department.
1. Reduce the number of simultaneously active protection zones (MD).
2. Modify part program:
- Delete other protection zones.
- Preprocessing stop.
When the alarm occurs during control ramp-up, the system variables $SN_PA_... have to be corrected for the specified
protection zone. Afterwards perform a restart. If the erroneous data cannot be recognized, the protection zone's imme-
diate activation can be removed, and the system variables of the protection zone can be written again by means of
NPROTDEF.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
If the alarm occurs during NC program execution, the current block can be changed. This way, the NPROT parameters
can also be adjusted. However, if there is an error in the definition of the protection zone, the NC program must be
aborted and the definition must be corrected under NPROTDEF.
If the alarm occurs on control ramp-up, system variables $SN_PA_... must be corrected for the specified protection
zone. This can be done by downloading an Initial.ini file that includes the relevant corrected date. If afterwards a restart
is performed again, the alarm will have been removed provided that the data are consistent.
18003
[Channel %1: ] Block %2 channel-specific protection zone %3 cannot be activated.
Error code %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of the channel-specific protection zone
%4 = Error specification
Definitions:
An error has occurred on activating the protection zone. The error number gives the specific reason for the alarm.
No.Meaning
1: Incomplete or conflicting contour definition.
2: Contour encompasses more than one surface area.
3: Tool-related protection zone is not convex.
4: If both boundaries are active in the 3rd dimension of the protection zone and both limits have the same value.
5: The number of the protection zone does not exist (negative number, zero or greater than the maximum number of
protection zones).
6: Protection zone definition consists of more than 10 contour elements.
7: Tool-related protection zone is defined as inside protection zone.
8: Incorrect parameter used.
9: Protection zone to be activated is not defined or number of the contour element <2 or
>MAXNUM_CONTOURNO_PROTECTAREA.
10: Error in internal structure of the protection zones.
11: Other, not further specified errors.
12: The number of protection zones simultaneously active exceeds the maximum number (channel-specific machine
data).
13,14: Contour element for protection zones cannot be created.
15,16: No more memory space for the protection zones.
17: No more memory space for the contour elements.
292
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents