6500

NC memory full

Definitions:
The NCK file system is full.
The available buffered memory does not suffice. Note: At first commissioning, files of the NC file system may be
affected such as drive data, MMC files, FIFO files, NC programs...
Reaction:
Alarm display.
Remedy:
Adjust the size of the buffered memory (MD18230 $MN_MM_USER_MEM_BUFFERED) or increase the space avail-
able in the buffered memory, e.g. by unloading part programs that are no longer being used. Or decrease the size of
the ring buffer (see $MC_RESU_RING_BUFFER_SIZE).
Program
Clear alarm with the Delete key or NC START.
Continuation:
6510

Too many part programs in the NC memory

Definitions:
The maximum number of possible files in the NC file system (part of the NC memory) has been reached. Note: During
first commissioning, this can affect files from the NC file system, e.g. drive data, MMC files, FIFO files, NC programs, ...
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Delete or unload files (e.g. part programs), or
- Increase MD18320 $MN_MM_NUM_FILES_IN_FILESYSTEM.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6520

The value of the machine data %1%2 is too low

Parameters:
%1 = String: MD identifier
%2 = If required, index: MD array
Definitions:
The MD18370 $MN_MM_PROTOC_NUM_FILES specifies the number of protocol files for the protocol users. How-
ever, more types are used than configured.
Reaction:
Alarm display.
Remedy:
Increase MD18370 $MN_MM_PROTOC_NUM_FILES.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6530

Too many files in directory

Definitions:
The number of files in a directory of the NC memory has reached the maximum limit.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Delete or unload files (e.g. part programs) in the respective directory, or
- Increase MD18280 $MN_MM_NUM_FILES_PER_DIR.
Program
Clear alarm with the Delete key or NC START.
Continuation:
Alarms