[Channel %1:] Spindle %2 Declaration As Modulo Axis Missing; [Channel %1:] Spindle %2 Declared Repeatedly; [Channel %1:] Axis %2 Declaration As Rotary Axis Missing - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Remedy:
Please inform the authorized personnel/service department. Set rotary axis declaration for this machine axis in the
axis-specific MD30300 $MA_IS_ROT_AX.
Program
Switch control OFF - ON.
Continuation:
4215
[Channel %1: ] Spindle %2 declaration as modulo axis missing
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The spindle functionality requires a modulo axis (positions in [deg]).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Set MD30310 $MA_ROT_IS_MODULO.
Program
Switch control OFF - ON.
Continuation:
4220
[Channel %1: ] Spindle %2 declared repeatedly
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The spindle number exists more than once in the channel.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
The spindle number is stored in the axis-specific MD35000 $MA_SPIND_ASSIGN_TO_MACHAX. The channel to
which this machine axis/spindle is assigned is listed in the machine axis index. (The machine axis number is given in
the channel-specific MD20070 $MC_AXCONF_MACHAX_USED).
Program
Switch control OFF - ON.
Continuation:
4225
[Channel %1: ] Axis %2 declaration as rotary axis missing
Parameters:
%1 = Channel number
%2 = Axis name, axis number
Definitions:
The modulo functionality requires a rotary axis (positions in [deg]).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Set MD30300 $MA_IS_ROT_AX.
Program
Switch control OFF - ON.
Continuation:
Alarms