Block %2 Address %3 Programmed Repeatedly; Block %2 Address %3 Address Type Programmed Too Often; Block %2 Illegal Address Modification - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

12000
[Channel %1: ] Block %2 address %3 programmed repeatedly
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string of the address
Definitions:
Most addresses (address types) may only be programmed once in an NC block, so that the block information remains
unambiguous (e.g. X... T... F... etc. - exception: G and M functions).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECT. The cor-
rection pointer positions on the incorrect block.
- Remove from the NC program addresses that occur more than once (except for those where multiple value assign-
ments are allowed).
- Check whether the address (e.g. the axis name) is specified via a user-defined variable (this may not be easy to see
if allocation of the axis name to the variable is performed in the program through computational operations only).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12010
[Channel %1: ] Block %2 address %3 address type programmed too often
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string of the address
Definitions:
The number of times each address type may occur in a NC block is defined internally (for instance, all axes together
form one address type to which a block limit also applies).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM CORRECTION. The
correction pointer positions on the incorrect block.
The program information must be split up over several blocks (but make sure that the functions are of the non-modal
type!).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12020
[Channel %1: ] Block %2 illegal address modification
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Valid address types are 'IC', 'AC', 'DC', 'CIC', 'CAC', 'ACN', 'ACP', 'CACN', 'CACP'. Not each of these address modifi-
cations can be used for each address type. The Programming Guide specifies which of these can be used for the var-
ious address types. If this address modification is applied to address types that are not allowed, then the alarm is
generated, e.g.:
N10 G02 X50 Y60 I=DC(20) J30 F100
interpolation parameters with DC.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Key: Press the NC STOP key and select the function "Correction block" with the softkey PROGRAM CORRECT. The
correction pointer is then positioned on the incorrect block.
Apply non-modal address modifications only for permissible addresses, in accordance with the Programming Manual.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
105

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents